Parameter Requirement Units
Frequency Range 70Mhz to 6Ghz as indicated
Configuration (Matrix Topology) 5 x 8 Matrix (40 Paths) as indicated
Impedance 50 Ohm
Insertion Loss (including internal attenuator & cable losses 15 typical dB
Insertion Loss Repeatability < 0.2 typical dB
Frequency Response Flatness 0.5 dB per any 10 MHz band from 70MHz to 6GHz dB
Return Loss (any port)/Bandwidth 15 dB min, 70MHz to 2GHz as indicated
Return Loss (any port)/Bandwidth 8 dB min, 2GHz to 6GHz as indicated
IP3 (Input) > +50 dBm
P1dB (Input) > +30 dBm 70Mhz to 6GHz as indicated
Maximum Rated Peak Power +33 dBm
Isolation (common to any non-selected output) > 40 dB 70MHz to 6GHz as indicated
Switching Speed (including settling time) < 1.0 to 0.1 dB of steady state ms
Insertion Loss Temperature Coefficient < 0.005 as indicated
Life Cycle Reliability 25 Million cycles minimum as indicated
Control Interface USB (Driver supplied) n/a
Supply Voltage 100, 120, 220, 240 V AC or USB as indicated
Control Connectors USB n/a
RF/MW Connectors N Type n/a
size 19" Rack Case 4U x 500mm deep as indicated

More Information

overview , interface , s parameters

If you would like to discuss how Amfax can help you deploy any of the technology, innovation or expertise you have seen in this case study, please contact us

Amfax Ltd Test & Measurement Solutions
Unit 3 Clump Farm Ind. Est. • Blandford • Dorset • UK
Tel: +44(0)1258 480777 • Fax: +44(0)1258 480777
Company Reg. 63584778 • VAT no. 2588994777
• 25 years of test innovation •